Call: 414-327-1555| 
 
 · AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC · Contact arrangement up to 4PDT · Wide selection of termination and mounting styles. · PC terminals available. · Push to test button and indicator lamps. · KUEP incorporates a blow out magnet for high voltage DC switching. · KUIP/KUGP are VDE approved. · Complete line of sockets and DIN rail. · Class B coil insulation. 
Arrangements:   See respective ordering information table.
Materials: Fine Silver (5 Amp) silver-cadmium oxide (10 Amp).
           Gold flash available as standard.
           Gold diffused and gols alloy on special order.
Expected Mechanical Life:
CONTACT RATINGS
Material   Arrangement     UL/CSA Ratings                  Expected
                                                           Life
Fine       All             5 amps @ 28VDC or 240VAC
Silver                     80% PF, 2.5 amp tungsten
                           @ 120VAC, 1/2 amp @ 120VDC      100,000
                           1/6HP @ 120VAC, 1/3HP @
                           240VAC, 5 FLA, 15 LRA @ 
                           250VAC (FLA covered by
                           30,000 operations).
Silver-    1-2 Pole        10 amps @ 28VDC or 240VAC,
Cadmium    KUP             80% PF, 5 amp tungsten @
Oxide      KUIP            120VAC, 3A 600VAC, 1/2 amp
           KUGP            @ 120VDC.                        100,000
           KUEP            1/3HP @ 120VAC, 1/2HP @
           All KUMP        240, 480, and 600VAC, 10 FLA
                           30 LRA @ 120VAC, 5 FLA,
                           15 LRA @ 250VAC, (FLA ratings
                           covered by 30,000 operations).
           KUMP            15 amp @ 277VAC, 80% PF
                           KUM KUMP                         100,000
           3 Pole          10 amp @ 28VDC or 120VAC
           KUP             80% PF, 6 2/3 amp @ 240VAC
           KUIP            80% PF                           100,000
           4 Pole          10 amp per pole not to exceed
                           30 amp total @ 28VDC, 120VAC,
                           80% PF, 6 2/3 amp @ 240VAC,
                           80% PF                           100,000
           KUEP
           SPST-NO         10 amp @ 150VDC
           KUEP
           2PST-NO         5 amp @ 150VDC
           KUEP
           2PDT            3 amp @ 150VDC                   100,000
(All other AC ratings apply KUEP)
Voltage: From 6 to 110VDC, and 6 to 240VAC Nominal Coil Power: DC Coils: 1.2W - KUP, KUIP, KUMP, 1-3 pole; KUEP, 1 pole. DC Coils: 1.8W - KUP, 4 pole; KUEP, 2 pole; KUGP. AC Coils: 2.0VA - KUP, KUIP, 1-2 pole; KUEP, 1 pole. AC Coils: 2.7VA - KUP, KUIP, 3 pole; KUEP, 2 pole; KUGP, KUMP. DC Volts 1.2 Watt 1.8 Watt Nominal DC Ohms +/-10% Nom. I ma DC Ohms +/-10% Nom. I ma 5 21 238 14 360 6 32.1 187 20 300 12 120 100 80 150 24 472 51 320 75 48 1,800 26.7 1,260 38 110 10,000 11 6,720 16 AC Volts 2VA 2.7 VA Nominal DC Ohms +/-15% Nom. I ma DC Ohms +/-15% Nom. I ma 6 6 335 4.2 460 12 24 168 18 230 24 85 84 72 115 120 2,250 17.5 1,700 24 240 9,110 8.75 7,200 12 Must-Operate Voltage: AC Coil: 85% of nominal voltage or less. DC Coil: 75% of nominal voltage or less. Operating Time (Excluding Bounce): 15 milliseconds, typical, at nominal voltage. Release Time (Excluding Bounce): 10 milliseconds, typical, at nominal voltage. 
Temperature Range:
  Operating: Enclosed Relays: -45C to maximum listed in table below.
             Open Relays:  Add 15C to maximum listed.
Max C   +45C        +50C        +55C        +70C        +75C        +80C        +95C
 KUP    AC          DC          AC          DC
        3-4 pole    4 pole      1-2 pole    1-3 pole
KUIP                                        AC                      AC          DC
                                            3 pole                  1-2 pole    1-3 pole
KUGP                                        AC           DC
                                            2 pole       2 pole
KUEP    AC          DC          AC          DC
        2 pole      2 pole      1 pole      1 pole
KUMP    AC                      AC          DC
        3 pole                  1-2 pole    1-3 pole
OUTLINE DIMENSIONS  | 
![]()  | 
Call: 414-327-1555 Fax : 414-327-0577 Email: iebyross@yahoo.com Catalog, Quote, Availability. © 2011 SYNsCON © 2011 Industrial Electronics Corp. of Wisconsin  |